phone-icon 01293 821345   email icon This email address is being protected from spambots. You need JavaScript enabled to view it.


The Old Rectory

The Old Rectory


isoenergy was asked to supply a complete heating and hot water solution for the main residence and the barn via heat pumps but with only a single-phase electricity supply available.

Solution:
To install 3 x Air to Water heat pumps, providing a total of 33 kW of heating and hot water capacity.

Each pump requires a running current of 21.5 amps.
An SMO10 controller ensures that each heat pump is called in as demand rises thus not exceeding the capacity of the single-phase supply, yet providing the necessary peak capacity when required. High quality pre-insulated pipe ensures maximum efficiency and minimum heat loss in transmission.